Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Res. Biomed. Eng. (Online) ; 33(1): 11-20, Mar. 2017. tab, graf
Article in English | LILACS | ID: biblio-842477

ABSTRACT

Abstract Introduction Cardiovascular diseases (CVD) have been the focus of research in recent years due to its high mortality rate. It is estimated that 17.5 million people died of CVD in 2012, from which 7.4 million were due to coronary heart disease (CHD). In order to monitor CHD patients and avoid waste of specialists' time, this study proposes the development of a method that segments the area contained by stent struts from Frequency Domain Intravascular Optical Coherence Tomography (the latest technology to view vessels internally) of coronary arteries. Methods The novelty of this study is to find areas comprised by stent struts using two optimal strategies that are robust even with false positives and false negatives detection of stent struts. The first one uses an ellipse fitting algorithm and the other uses a cylinder fitting algorithm. Results Both strategies obtained similar accuracy results close to 98% of true positives, but the cylinder technique showed a run time of at least 50 times higher than the ellipse technique. Conclusion The methods were executed on 443 images with different characteristics showing robustness and usefulness in the medical area.

2.
Res. Biomed. Eng. (Online) ; 33(1): 1-10, Mar. 2017. tab, graf
Article in English | LILACS | ID: biblio-842485

ABSTRACT

Abstract Introduction Numerical phantoms are important tools to design, calibrate and evaluate several methods in various image-processing applications, such as echocardiography and mammography. We present a framework for creating ultrasound numerical deformable phantoms based on Finite Element Method (FEM), Linear Isomorphism and Field II. The proposed method considers that the scatterers map is a property of the tissue; therefore, the scatterers should move according to the tissue strain. Methods First, a volume representing the target tissue is loaded. Second, parameter values, such as Young’s Modulus, scatterers density, attenuation and scattering amplitudes are inserted for each different regions of the phantom. Then, other parameters related to the ultrasound equipment, such as ultrasound frequency and number of transducer elements, are also defined in order to perform the ultrasound acquisition using Field II. Third, the size and position of the transducer and the pressures that are applied against the tissue are defined. Subsequently, FEM is executed and deformation is computed. Next, 3D linear isomorphism is performed to displace the scatterers according to the deformation. Finally, Field II is carried out to generate the non-deformed and deformed ultrasound data. Results The framework is evaluated by comparing strain values obtained the numerical simulation and from the physical phantom from CIRS. The mean difference between both phantoms is lesser than 10%. Conclusion The acoustic and deformation outcomes are similar to those obtained using a physical phantom. This framework led to a tool, which is available online and free of charges for educational and research purposes.

3.
Rev. bras. eng. biomed ; 30(2): 159-172, Apr.-June 2014. ilus, graf, tab
Article in English | LILACS | ID: lil-714731

ABSTRACT

INTRODUCTION: The rupture of atherosclerotic plaques causes millions of death yearly. It is known that the kind of predominant tissue is associated with its dangerousness. In addition, the mechanical properties of plaques have been proved to be a good parameter to characterize the type of tissue, important information for therapeutic decisions. METHODS: Therefore, we present an alternative and simple way to discriminate tissues. The procedure relies on computing an index, the ratio of the plaque area variation of a suspecting plaque, using images acquired with vessel and plaques, pre and post-deformation, under different intraluminal pressure. Numerical phantoms of coronary cross-sections with different morphological aspects, and simulated with a range of properties, were used for evaluation. RESULTS: The outcomes provided by this index and a widely used one were compared, so as to measure their correspondence. As a result, correlations up to 99%, a strong agreement with Bland-Altman and very similar histograms between the two indices, have shown a good level of equivalence between the methods. CONCLUSION: The results demonstrated that the proposed index discriminates highly lipidic from fibro-lipidic and calcified tissues in many situations, as good as the widely used index, yet the proposed method is much simpler to be computed.

4.
Rev. bras. eng. biomed ; 29(1): 32-44, jan.-mar. 2013. graf, tab
Article in Portuguese | LILACS | ID: lil-670972

ABSTRACT

No ano 2010, doenças cardiovasculares (CVD) causaram 33% do total das mortes no Brasil. Tomografia Ótica Coerente Intravascular (IOCT) é uma tecnologia que oferece imagens in vivo para detecção e monitoramento da progressão de CVD. O exame de IOCT permite mais precisão no diagnóstico; contudo, ainda é pequena a variedade de métodos quantitativos aplicados a IOCT na literatura, em comparação à outras modalidades relacionadas. Portanto neste trabalho é proposto um método de segmentação do lúmen, baseado em uma combinação de Fuzzy Connectedness, com múltiplas funções de afinidade, e Operações Morfológicas. As funções de afinidade usadas neste trabalho são: (I) Clássica, (II) Pesos Dinâmicos e (III) Bhattacharyya. Esta última é baseada no coeficiente de Bhattacharyya, utilizado habitualmente para speckle tracking. Primeiro, características não desejadas da imagem são atenuadas. Depois, informações da parede do vaso são obtidas utilizando Fuzzy Connectedness e um processo de binarização dinâmico. Finalmente, operações morfológicas são realizadas para melhorar o lúmen segmentado. Para avaliar o método proposto, um conjunto de 130 imagens advindas de humanos, porcos, e coelhos foram segmentadas e comparadas com seus respectivos "Gold Standards" feitos por especialistas. Uma média de verdadeiros positivos (TP%) = 98,08 e de falsos positivos (FP%) = 2,34 foram obtidas. Com isso, o método proposto resultou em uma maior eficácia do que os estudos publicados anteriormente, encorajando seu uso.


In 2010 cardiovascular disease (CVD) caused 33% of the total deaths in Brazil. Intravascular Optical Coherent Tomography (IOCT) is an imaging technology that provides in vivo detection and monitoring of the progression of coronary heart disease. IOCT exam allows more accurate diagnoses; nonetheless, the set of quantitative methods applied to IOCT in the literature is small compared to other related modalities. Therefore, the proposed approach presents a lumen segmentation method, based on a combination of Fuzzy Connectedness, with multiple affinity functions, and Morphological Operations. The affinity functions used in this work are: (I) classical, (II) Dynamic weights (III) Bhattacharyya. The latter is based on the Bhattacharyya coefficient, commonly used for speckle tracking. Firstly, unwanted features of the image are attenuated. Then, vessel-wall information is obtained using Fuzzy Connectedness and dynamic binarization process. Finally, morphological operations are performed to improve the segmented lumen. To evaluate the proposed method, a set of 130 images from humans, pigs and rabbits were segmented and compared to their corresponding gold standard made by experts. An average of true positive (TP%) = 98.08, and false positive (FP%) = 2.34 were obtained. Hence, the use of the proposed method is suggested since it has yielded higher efficiency than previously published studies.

5.
Rev. bras. eng. biomed ; 29(1): 70-85, jan.-mar. 2013. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-670975

ABSTRACT

A Medicina Nuclear, como especialidade de obtenção de imagens médicas é um dos principais procedimentos utilizados hoje nos centros de saúde, tendo como grande vantagem a capacidade de analisar o comportamento metabólico do paciente. Este projeto está baseado em imagens médicas obtidas através da modalidade PET (Positron Emission Tomography). Para isso, foi desenvolvida uma estrutura de processamento de imagens tridimensionais PET, constituída por etapas sucessivas que se iniciam com a obtenção das imagens padrões (gold standard), sendo utilizados para este fim volumes simulados do Ventrículo Esquerdo do Coração criadas como parte do projeto, assim como phantoms gerados com o software NCAT-4D. A seguir, nos volumes simulados é introduzido ruído Poisson que é o ruído característico das imagens PET. Na sequência é executada uma etapa de pré-processamento, utilizando alguns filtros 3D tais como o filtro da mediana, o filtro da Gaussiana ponderada e o filtro Anscombe/Wiener. Posteriormente é aplicada a etapa de segmentação, processo baseado na teoria de Conectividade Fuzzy sendo implementadas quatro diferentes abordagens 3D: Algoritmo Genérico, LIFO, kTetaFOEMS e Pesos Dinâmicos. Finalmente, um procedimento de avaliação conformado por três parâmetros (Verdadeiro Positivo, Falso Positivo e Máxima Distância) foi utilizado para mensurar o nível de eficiência e precisão do processo. Constatou-se que o par Filtro - Segmentador constituído pelo filtro Anscombe/Wiener junto com o segmentador Fuzzy baseado em Pesos Dinâmicos proporcionou os melhores resultados, com taxas de VP e FP na ordem de 98,49 ± 0,27% e 2,19 ± 0,19%, respectivamente, para o caso do volume do Ventrículo Esquerdo simulado. Com o conjunto de escolhas feitas ao longo da estrutura de processamento, encerrou-se o projeto analisando um número reduzido de volumes pertencentes a um exame PET real, obtendo-se a quantificação dos volumes.


The Nuclear medicine, as a specialty to obtain medical images is very important, and it has became one of the main procedures utilized in Health Care Centers to analyze the metabolic behavior of the patient. This project was based on medical images obtained by the PET modality (Positron Emission Tomography). Thus, we developed a framework for processing Nuclear Medicine three-dimensional images of the PET modality, which is composed of consecutive steps that start with the generation of standard images (gold standard) by using simulated images of the Left Ventricular Heart, such as phantoms obtained from the NCAT-4D software. Then, Poisson quantum noise was introduced into the whole volume to simulate the characteristic noises in PET images. Subsequently, the pre-processing step was executed by using specific 3D filters, such as the median filter, the weighted Gaussian filter, and the Anscombe/Wiener filter. Then the segmentation process, which is based on the Fuzzy Connectedness theory, was implemented. For that purpose four different 3D approaches were implemented: Generic, LIFO, kTetaFOEMS, and Dynamic Weight algorithm. Finally, an assessment procedure was used as a measurement tool to quantify three parameters (True Positive, False Positive and Maximum Distance) that determined the level of efficiency and precision of our process. It was found that the pair filter - segmenter formed by the Anscombe/Wiener filter together with the Fuzzy segmenter based on Dynamic Weights provided the best results, with VP and FP rates of 98.49 ± 0.27% and 2.19 ± 0.19%, respectively, for the simulation of the Left Ventricular volume. Along with the set of choices made during the processing structure, the project was finished with the analysis of a small number of volumes that belonged to a real PET test, thus the quantification of the volumes was obtained.

6.
Rev. bras. eng. biomed ; 27(4): 231-242, dez. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-613999

ABSTRACT

O presente trabalho objetiva a seleção do modelo compartimental mais adequado ao estudo da dinâmica fisiológica em exames de tomografia por emissão de pósitrons (PET). Para tanto, propõe-se utilizar o critério de informação de Akaike para a seleção do modelo, e a metodologia de equações de sensibilidade e o algoritmo de Levenberg-Marquardt para a tarefa de estimação de parâmetros característicos e, consequentemente, do erro residual da estimativa. São consideradas três estruturas compartimentais compostas, respectivamente, por dois compartimentos e duas constantes características, três compartimentos e quatro constantes características e quatro compartimentos e seis constantes características. Os dados considerados neste trabalho foram sintetizados preocupando-se em reunir as principais características de um exame de tomografia real, tais como tipo e nível de ruído e morfologia de função de excitação do sistema. Aplicando-se a metodologia proposta em três níveis de ruído (baixo, médio e alto), obteve-se concordância do melhor modelo em graus forte e considerável (com índices de Kappa iguais a 0,95, 0,93 e 0,63, respectivamente). Observou-se que, com elevado nível de ruído e modelos mais complexos (quatro compartimentos), a classificação se deteriora devido ao pequeno número de dados para a decisão. Foram desenvolvidos programas e uma interface gráfica que podem ser utilizados na investigação, elaboração, simulação, estimativa de parâmetros e identificação do modelo compartimental para apoio e análise de diagnósticos clínicos e práticas científicas.


The objective of this work is the determination of the most adequate compartmental model for the study of physiological dynamics based on positron emission tomography (PET) exams. We propose the use of Akaike’s information criterion for the optimal model selection, and Levenberg-Marquardt algorithm with sensitivity equations for the task of estimating the characteristic parameters of the differential equations describing the models. We have considered three compartmental structures represented, respectively, by two compartments and two characteristic constants, three compartments and four characteristic constants and four compartments and six characteristics constants. The data considered in this work were synthesized taking into account key features of a real tomography exam, such as type and level of noise and morphology of the input function of the system. Applying the proposed methodology with three noise levels (low, medium and high), we obtained agreement of the best model with strong and considerable degrees (with Kappa indexes equal to  0.95, 0.93 and  0.63, respectively). It was observed that, with high noise level and more complex models (four compartments), the classification is deteriorated due to lack of data for the decision. Programs have been developed and a graphical interface that can be used in research, development, simulation and parameter identification of compartmental models, supporting analysis of clinical diagnostics and scientific practices.


Subject(s)
Humans , Positron-Emission Tomography/instrumentation , Positron-Emission Tomography , /methods
7.
Rev. bras. eng. biomed ; 26(3): 219-233, dez. 2010. ilus, tab
Article in English | LILACS | ID: lil-595062

ABSTRACT

Por ser capaz de mostrar aspectos morfológicos e patológicos de ateroscleroses, o Ultrassom Intravascular (IVUS) se tornou uma das modalidades de imagens médicas mais confiáveis e empregadas em intervenções cardíacas. As características de sua imagem aumentam as chances de um bom diagnóstico, resultando em terapias mais precisas. O estudo de segmentação da fronteira média-adventícia, dentre muitas aplicações, é importante para o aprendizado das propriedades mecânicas e determinação de algumas medidas específicas (raio, diâmetro, etc.) em vasos e placas. Neste trabalho, uma associação de técnicas de processamento de imagens está sendo proposta para atingir alta acurácia na segmentação da borda média-adventícia. Para tanto, foi feita uma combinação das seguintes técnicas: Redução do Speckle por Difusão Anisotrópica (SRAD), Wavelet, Otsu e Morfologia Matemática. Primeiramente, é usado SRAD para atenuar os ruídos speckle. Posteriormente, é executada Transformada Wavelet para extração das características dos vasos e placas. Uma versão binarizada dessas características é criada na qual o limiar ótimo é definido por Otsu. Finalmente, é usada Morfologia Matemática para obtenção do formato da adventícia. O método proposto é avaliado ao segmentar 100 imagens de alta complexidade, obtendo uma média de Verdadeiro Positivo (TP(%)) = 92,83 ± 4,91, Falso Positivo (FP(%)) = 3,43 ± 3,47, Falso Negativo (FN(%)) = 7,17 ± 4,91, Máximo Falso Positivo (MaxFP(mm)) = 0,27 ± 0,22, Máximo Falso Negativo (MaxFN(mm)) = 0,31 ± 0,2. A eficácia do nosso método é demonstrada, comparando este resultado com outro trabalho recente na literatura.


By being able to show morphological and pathological aspects of atherosclerosis, the Intravascular Ultrasound (IVUS) be¬came one of the most reliable and employed medical imaging modality in cardiac interventions. Its image characteristics in¬crease the chances of a good diagnostic, resulting in a precise therapy. The study of media-adventitia borders segmentation in IVUS, among many applications, is important for learning about the mechanical properties and determining some specific measurements (radius, diameter, etc.) in vases and plaques. An approach is proposed to achieve high accuracy in media-adventitia borders segmentation, by making a combination of different image processing operations: Speckle Reducing Anisotropic Diffusion (SRAD), Wavelet, Otsu and Mathematical Morphology. Firstly, SRAD is applied to attenuate the speckle noise. Next, the vessel and plaque features are extracted by performing Wavelet Transform. Optimal thresholding is car¬ried out by Otsu method to create a binarized version of these features. Then, Mathematical Morphology operations are used to obtain an adventitia shape. The proposed approach is evaluated by segmenting 100 challenging images, obtaining an average of True Positive (TP(%)) = 92.83 ± 4.91, False Positive (FP(%)) = 3.43 ± 3.47, False Negative (FN(%)) = 7.17 ± 4.91, Max False Positive (MaxFP(mm)) = 0.27 ± 0.22, Max False Negative (MaxFN(mm)) = 0.31 ± 0.2. The effectiveness of our approach is demonstrated by comparing this result with another recent work in the literature.


Subject(s)
Atherosclerosis , Ultrasonography, Interventional/instrumentation , Ultrasonography, Interventional/trends , Ultrasonography, Interventional , Image Enhancement/instrumentation , Endothelium, Vascular , Image Processing, Computer-Assisted/instrumentation , Image Processing, Computer-Assisted/trends , Image Processing, Computer-Assisted
8.
Clinics ; 64(6): 571-576, June 2009. tab
Article in English | LILACS | ID: lil-517927

ABSTRACT

INTRODUCTION: The present study was motivated by the need to systematically assess the research productivity of the Heart Institute (InCor), Medical School of the University of São Paulo, Brazil.OBJECTIVE: To explore methodology for the assessment of institutional scientific research productivity. MATERIALS AND METHODS: Bibliometric indicators based on searches for author affiliation of original scientific articles or reviews published in journals indexed in the databases Web of Science, MEDLINE, EMBASE, LILACS and SciELO from January 2000 to December 2003 were used in this study. The retrieved records were analyzed according to the index parameters of the journals and modes of access. The number of citations was used to calculate the institutional impact factor. RESULTS: Out of 1253 records retrieved from the five databases, 604 original articles and reviews were analyzed; of these, 246 (41%) articles were published in national journals and 221 (90%) of those were in journals with free online access through SciELO or their own websites. Of the 358 articles published in international journals, 333 (93%) had controlled online access and 223 (67%) were available through the Capes Portal of Journals. The average impact of each article for InCor was 2.224 in the period studied. CONCLUSION: A simple and practical methodology to evaluate the scientific production of health research institutions includes searches in the LILACS database for national journals and in MEDLINE and the Web of Science for international journals. The institutional impact factor of articles indexed in the Web of Science may serve as a measure by which to assess and review the scientific productivity of a research institution.


Subject(s)
Humans , Bibliometrics , Biomedical Research/standards , Cardiology/statistics & numerical data , Periodicals as Topic/statistics & numerical data , Brazil , Biomedical Research/statistics & numerical data , Cardiac Care Facilities/standards , Cardiac Care Facilities/statistics & numerical data , Databases, Bibliographic/statistics & numerical data , Journal Impact Factor , Periodicals as Topic/standards
9.
Rev. bras. eng. biomed ; 23(1): 53-77, abr. 2007. ilus
Article in Portuguese | LILACS | ID: lil-483524

ABSTRACT

Com a disseminação dos sistemas informatizados para a área da saúde, a questão da segurança da informação passa a assumir uma importância cada vez mais crucial, visando principalmente resguardar um dos direitos fundamentais do paciente, qual seja, a privacidade das suas informações acerca da saúde da pessoa pode acarretar danos irreparáveis de ordem física e moral. Além disso, o comprometimento da confiabilidade de tais informações pode minar a credibilidade das instituições de saúde e prejudicar a pesquisa, na medida em que dados incorretos levarão naturalmente a diagnósticos e resultados incorretos. Apesar da relevância que a segurança possui, o desenvolvimento de soluções voltadas para a área médica é algo relativamente recente. Isso porque existem várias características específicas para esta área, o que requer uma visão sobre o contexto das informações médicas - em particular, os asapectos éticos e legais - para que se possa atender de forma adequada os seus requisitos e implantar os mecanismos tecnológicos condizentes. Este artigo apresenta um panorama geral da segurança em informações médicas, fazendo primeiramente algumas considerações chave sobre a segurança da informação de um modo geral e o contexto de segurança na área médica, para então mostrar asa propostas e implementações realizadas em várias frentes visando garantir os diferentes aspectos da segurança das informações médicas.


Subject(s)
Computer Security , Medical Records Systems, Computerized/trends , Medical Records Systems, Computerized , Medical Informatics/trends , Electronic Data Processing/methods , Information Systems/standards , Information Systems/trends , Information Systems
10.
Mundo saúde (Impr.) ; 24(3): 182-6, maio.-jun. 2000. ilus, tab
Article in Portuguese | LILACS, SES-SP | ID: lil-264189

ABSTRACT

A distribuição dos serviços de saúde e o compartilhamento de informações clínicas, utilizando sistemas de telecomunicação, envolvem um conjunto diverso e complexo de tecnologias. Além disso, se a informação a ser compartilhada contém imagens, um problema especial em cardiologia é como distribuir imagens dinâmicas obtidas em estudos de ecocardiografia e de angiografia com qualidade de serviço. As imagens individuais são facilmente transmitidas, mas o volume total, considerando todas as imagens em uma seqüência, é enorme podendo chegar facilmente na ordem de Giga Bytes por paciente. Os avanços em tecnologias de comunicações e em informática facilitam a médicos e especialistas localizados em um centro de referência a troca de informações com médicos e profissionais de saúde em local distante, em outro centro, ou mesmo com o próprio paciente. Embora em especialidades como cardiologia, radiologia e patologia, as informações relevantes sobre o paciente sejam inerentemente digitais, a necessidade de alta qualidade associada ao volume de dados impõem limitações na prática de ações de Medicina à distância através dos meios de comunicação convencionais


Subject(s)
Medical Laboratory Science , Diagnostic Imaging , Information Systems , Telecommunications
11.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.371-372.
Monography in Portuguese | LILACS | ID: lil-236399

ABSTRACT

Neste trabalho, apresenta-se uma solução alternativa para a reconstrução de imagens tomográficas em Medicina Nuclear que usa o modelo de ruído de Poisson. O algoritmo proposto foi aplicado a um phantom físico e comparada com a metodologia usual de reconstrução em rotina clínica. A análise dos resultados mostrou que a aplicação do método melhora a qualidade das imagens reconstruídas.


We present an altemative solution for the reconstruction of SPECT images using a Poisson Noise Model. The proposed algorithm was applied on a real phantom and compared to the standard clinica! procedure. Results have shown that the proposed method improves the quality ofthe SPECT images.


Subject(s)
Image Processing, Computer-Assisted , Phantoms, Imaging , Poisson Distribution , Tomography, Emission-Computed, Single-Photon/methods , Noise , Diagnostic Imaging , Normal Distribution
12.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.367-368.
Monography in Portuguese | LILACS | ID: lil-236397

ABSTRACT

Apresentamos um método para a determinação automática das regiões de interesse em estudos de ventriculografia radioisotópica (VR). O método utiliza informações a priori sobre a localização do ventrículo esquerdo (VE), além de uma versão modificada do operador Lapraciano da Guassiana conjugado com operações de morfologia matemática. O algoritmo apresenta boa correlação com o procedimento manual, além de ser rápido e robusto.


We present a method for the automatic determination of regions of interest in gated blood pool studies. The method uses a priori information about left ventricle location, and a modified version of the Laplacian of Gaussian operator is applied with some mathematical morphology operations, yielding the final regions. The algorithm showed to be highly correlated to the manual procedure, besides being to be fast and robust.


Subject(s)
Humans , Female , Infant , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Heart Ventricles , Radionuclide Ventriculography/methods , Radial Filters , Velocity Gradient
SELECTION OF CITATIONS
SEARCH DETAIL